Sign In
Labcorp Oklahoma, Inc.
Test Directory


Index:

Rufinamide (Banzel) Serum/Plasma

Order Name RUFINAMIDE
Test Number: 3804077
Revision Date 12/12/2022
Test Name Methodology LOINC Code
Rufinamide (Banzel) Serum/Plasma
Quantitative Liquid Chromatography/Tandem Mass Spectrometry 59323-6 
SPECIMEN REQUIREMENTS
Specimen Specimen Volume (min) Specimen Type Specimen Container Transport Environment
Preferred 2 mL (0.5 mL) Serum Clot Activator (Red Top, No-Gel) Refrigerated
Alternate 1 2 mL (0.5 mL) Plasma EDTA (Lavender Top) Refrigerated
Instructions Notes: 0.5 mL (Note: This volume Does NOT allow for repeat testing).
Specimen Type: Green-top (heparin) tube or red-top tube NOTE: Gel-barrier tubes NOT recommended.
Specimen Collection: Serum or plasma should be separated from cells within two hours of venipuncture. Send serum or plasma in a plastic transport tube.
Special Instructions: Testing referred to MEDTOX Laboratories, Inc. TC 445
Specimen Storage /Stability: SUBMISSION/TRANSPORT (<3 days): Room Temperature. For storage beyond three days, specimen should be refrigerated or frozen.
GENERAL INFORMATION
Expected TAT 4 - 10 days   
Performing Labcorp Test Code 284191 
Notes Labcorp Test Code: 284191
CPT Code(s) 80210
Lab Section Reference Lab