Flecainide (Tambocor)
Order Name
TAMBOCOR
Test Number: 3618200
Revision Date 12/12/2022
Test Number: 3618200
Revision Date 12/12/2022
Test Name | Methodology | LOINC Code |
---|---|---|
Flecainide (Tambocor)
|
Liquid Chromatography/Tandem Mass Spectrometry | 3638-4 |
SPECIMEN REQUIREMENTS | ||||
---|---|---|---|---|
Specimen | Specimen Volume (min) | Specimen Type | Specimen Container | Transport Environment |
Preferred | 1 mL (0.2 mL) | Serum | Clot Activator (Red Top, No-Gel) | Refrigerated |
Alternate 1 | 1 mL (0.2 mL) | Plasma | Lithium Heparin (Dark Green Top / No-Gel) | Refrigerated |
Instructions | Specimen Type: Red-top (no additive) tube or green-top (heparin) tube; gel-barrier tubes not recommended Specimen Storage: Refrigerated Specimen Collection: Transfer separated serum or plasma to a plastic transport tube. Draw immediately prior to next dose unless otherwise instructed. Specimen Stability: Ambient: 3 days, Refrigerated : 14 days, Frozen: 14 days |
GENERAL INFORMATION | |
---|---|
Expected TAT | 2 - 4 days working day. |
Clinical Use | Monitoring the flecainide concentration is used to assure compliance and avoid toxicity of this cardiac drug used to treat ventricular tachcardia and premature cardiac contractions. |
Performing Labcorp Test Code | 085662 |
Notes | Labcorp Test Code: 085662 |
CPT Code(s) | 80181 |
Lab Section | Reference Lab |