Platelet Antibody Indirect
Order Name
PLT Ab Indirect
Test Number: 5577425
Revision Date 01/17/2020
Test Number: 5577425
Revision Date 01/17/2020
Test Name | Methodology | LOINC Code |
---|---|---|
Platelet Antibody Indirect
|
Enzyme-Linked Immunosorbent Assay (ELISA) |
SPECIMEN REQUIREMENTS | ||||
---|---|---|---|---|
Specimen | Specimen Volume (min) | Specimen Type | Specimen Container | Transport Environment |
Preferred | 1mL (0.5mL) | Serum | Clot Activator SST | Frozen |
Instructions | Separate Serum from cells ASAP within 2 hours of collection. Serum can be refrigerated up 48 hours before frozen. |
GENERAL INFORMATION | |
---|---|
Testing Schedule | Mon-Thr |
Expected TAT | 1-3 Days |
Clinical Use | This test was previously known as the "Platelet Refractory Antibody" but has been renamed to "Platelet Antibody Indirect". This assay is designed to screen for antibodies to HLA class I and platelet glycoprotein IV antigens, and to polymorphic epitopes on the platelet glycoprotein IIb/IIIa, Ib/IX, Ia/IIa. |
CPT Code(s) | 86022 |
Internal Comments | 5/12/17 removed EDTA from Specimen type. - JK 11/06/17 added new clinical indication in prep - Alko Rename this test from “Platelet Refractory Antibody” tc 5577425 To be known as “Platelet Antibody Indirect” - JK 1/17/20 removed : Separate Serum from cells ASAP. Keep Serum refrigerated; however if specimen is not going to be tested within 48 hours then freeze the specimen. EDTA Plasma is No Longer Acceptable Specimen Type due to change from reagent vendor. - to have specimen frozen. |
Lab Section | Immunology - Serology |